The VR Series Systems are custom-engineered, heavy-duty systems, designed to be completely closed-loop with no external discharge. They incorporate an extremely efficient, patented filtration process utilizing fully automated solids filtration and activated carbon (GAC) polishing filtration, and a corona discharge ozone generator to prevent odors.
Processed water passing through the VR system will be free of particles greater than 10 microns in size, substantially all emulsified oils, waxes and other volatile organic compounds.
If water shortages and drought conditions are impacting your business, the VR Systems will help you reduce your fresh water usage, sewer discharge costs and local impact fees.
Why Do I Need a Re-Cyke® VR System?
The easiest way to reduce your water costs is to reduce your fresh water usage. Recycling wash water also eliminates EPA and local impact fees, reduces sanitary sewer costs, and water restrictions. VR Heavy-Duty systems are designed for washing cars, trucks, buses, equipment and other vehicles with sand, dirt, oil, and other commercial/industrial surface layers.
How Does the Re-Cyke® VR System Work?
The Re-Cyke® VR Recycling System pulls the used wash water through the gravity separation system to initially remove some solids, free oils, greases, and waxes. The water is then pumped through multiple solids and polishing filters. The water’s flow is injected with ozone gas for constant bacteria destruction and odor elimination. The treated water is constantly recirculated in a storage tank and re-pressurized for reuse upon demand.
STANDARD FEATURES:
- High-Efficiency Self-Priming Filter Pump
- Corona Discharge Ozonation System
- Multi-Stage / Multi-Pass Filtration
- Solids Filtration to 5 Microns
- Pressurized Carbon Polishing Filter
- High Efficiency Repressurization Pump
- Auto-Backwashing Filters
- Low Operating & Maintenance Costs
- Minimal Service Attention
OPTIONAL FEATURES:
- Can be configured with existing oil/water separators
- Available in partial reclaim or total closed loop configurations
- PLC control with remote monitoring
- Complete system enclosure
- Modular systems up to 500 gpm
- ORP / pH control system
- U.L. Listing
VR SERIES SYSTEM SPECIFICATIONS
MODEL | VR-5 | VR-10 | VR-35 | VR-65 | VR-100 |
FLOW RATE | 1-5 gpm | 1-10 gpm | 5-35 gpm | 30-75 gpm | 60-110 gpm |
RE-CIRCULATION PUMP | 3/4 hp | 1 1/2 hp | 3 hp | 3 hp | 5 hp |
INLET | 2” | 2” | 2” | 2” | 2” |
OUTLET | 1” | 1” | 2” | 2” | 2” |
RE-PRESSURIZATION PUMP | 1/2 hp | 1 hp | 3 hp | 5 hp | 7.5 hp |
WEIGHT (lbs.) | 625 | 650 | 750 | 850 | 950 |
KW (max.) | 1.8 | 2.0 | 3.0 | 4.0 | 5.0 |
OZONE SYSTEM | Up to 32 grams of ozone per hour | ||||
CONTROL SYSTEM | Automatic, Manual or Off | ||||
FOOTPRINT SIZE | 34” W X 66” L | 34” W X 66” L | |||
POWER REQUIREMENTS | 208 / 240 v 1 0 or 208 / 240 / 480 v 3 0 |